The Field Logger 512 k is a versatile, powerful and yet cost solution for handling analogue, digital and other types of variables with high resolution and speed. It has 8 configurable analogue inputs that can read thermocouples type J, K, T, E, N, R, S, B, Pt100, Pt1000, voltage and current signals. It also has 2 relay outputs and 8 digital ports individually configurable as inputs or outputs. The Field Logger 512 k reads and records the analogue variables. It works like an electronic data logger and records information for later analysis in its internal memory. It can also be used as a real-time control measurement module. Without the use of internal memory the Field Logger 512 k is possible to send data to an external monitoring system. This allows the logger to be used for a variety of applications. It is configurable through an easy-to-use software that runs on PC operation systems up from Windows 98®.
The 512 k logging basic memory is used to store data and can be expanded with a SD card. A optional available color Human-Machine-Interface (HMI) can be attached for local indication or configuration. The attached user friendly software can be accessed by Ethernet, USB or RS485 and also provides means for online monitoring, logged data downloading and exporting to spread sheets and other formats.
Features
-
8 universal analogue input channels:
- Thermocouples, Pt100 and Pt1000, V, mV, mA
- Reading and logging rates of up to 1000 measuring range/second
- 24 bit A / D conversion resolution
- 8 digital I/O (individually configured as input or output)
- 2 relay outputs (NO, NC and common)
- RS485 interface (Modbus master or slave)
- When acting as a master, can read up to 64 registers from other slaves
- Registers read can be used in logging, alarms or mathematical operations
- Ethernet interface with a lot of services available
- Sends alarm e-mails (SMTP)
- Provides web pages with channels and status information (HTTP)
- Allows logged data download via FTP (client and server)
- Allows Modbus communication by Ethernet interface (Modbus TCP)
- USB - device interface for configuring, monitoring and download
- USB - host interface for logged data retrieval through a USB flash drive
Find suitable accessory here:
Find suitable temperature probe here:
|
Technical Data
|
|
Measuring ranges
|
-90...+1820°C
depending on the connected sensor
|
Inputs for thermocouples type
|
J, K, T, E, N, R, S, B |
Inputs for
|
Pt100, Pt1000, DC linear/scaleable |
| Outputs |
2 x SPST-NA 3A/250V |
| Resolution |
24 bits |
| Device accuracy (at 25°C) for |
Thermocouples type J, K, T, E, N
Thermocouples type R, S, B
Pt100, Pt1000, 0-20 mA, 4-20 mA, 0-20 mV,
0-50 mV, 0-60 mV, 20-20 mV, 0-5 V, 0-10 V |
±0,2% of measuring range ±1°C
±0,2% of measuring range ±3°C
±0,15% |
Operating temperature
|
+5...+50°C |
Measuring rate
|
500 ms - 950 ms |
Memory capacity
|
512 k |
Power supply
|
100...240V AC 50/60 Hz |
Ingress protection
|
IP20 |
| Interface |
RS485 / USB |
Software language
|
English |
| Dimensions (W x H x D) |
162,5 x 117 x 70 mm |
|
Scope of Delivery
|
|
Field Logger 512 k incl. software, operating instruction on CD | |